Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 42.502
1.
2.
Arq Bras Cardiol ; 121(4): e20230544, 2024.
Article Pt, En | MEDLINE | ID: mdl-38695471

BACKGROUND: Ablation Index (AI) software has allowed better atrial fibrillation (AF) ablation results, but recurrence rates remain significant. Specific serum biomarkers have been associated with this recurrence. OBJECTIVES: To evaluate whether certain biomarkers could be used (either individually or combined) to predict arrhythmia recurrence after AI-guided AF ablation. METHODS: Prospective multicenter observational study of consecutive patients referred for AF ablation from January 2018 to March 2021. Hemoglobin, brain natriuretic peptide (BNP), C-reactive protein, high sensitivity cardiac troponin I, creatinine clearance, thyroid-stimulating hormone (TSH) and free thyroxine (FT4) were assessed for their ability to predict arrhythmia recurrence during follow-up. Statistical significance was accepted for p values of<0.05. RESULTS: A total of 593 patients were included - 412 patients with paroxysmal AF and 181 with persistent AF. After a mean follow-up of 24±6 months, overall single-procedure freedom from atrial arrhythmia was 76.4%. Individually, all biomarkers had no or only modest predictive power for recurrence. However, a TSH value >1.8 µUI/mL (HR=1.82 [95% CI, 1.89-2.80], p=0.006) was an independent predictor of arrhythmia recurrence. When assessing TSH, FT4 and BNP values in combination, each additional "abnormal" biomarker value was associated with a lower freedom from arrhythmia recurrence (87.1 % for no biomarker vs. 83.5% for one vs. 75.1% for two vs. 43.3% for three biomarkers, p<0.001). Patients with three "abnormal" biomarkers had a threefold higher risk of AF recurrence compared with no "abnormal" biomarker (HR=2.88 [95% CI, 1.39-5.17], p=0.003). CONCLUSIONS: When used in combination, abnormal TSH, FT4 and BNP values can be a useful tool for predicting arrhythmia recurrence after AI-guided AF ablation.


FUNDAMENTO: O software ablation index (AI) permitiu melhorar os resultados da ablação de fibrilação atrial (FA), mas as taxas de recorrência permanecem significativas. Biomarcadores séricos específicos têm sido associados a essa recorrência. OBJETIVOS: Avaliar se certos biomarcadores podem ser utilizados (individualmente ou combinados) para predizer a recorrência de FA pós ablação guiada pelo AI. MÉTODOS: Estudo multicêntrico, observacional, prospectivo de pacientes consecutivos, encaminhados para ablação de FA de janeiro de 2018 a março de 2021. Hemoglobina, peptídeo natriurético cerebral (BNP), proteína C reativa, troponina I ultrassensível, clearance de creatinina, Hormônio Tireoestimulante (TSH), e Tiroxina livre (T4) foram avaliados quanto à capacidade de prever a recorrência de arritmias durante o acompanhamento. Valores de p <0,05 foram aceitos como estatisticamente significativos. RESULTADOS: Um total de 593 pacientes foram incluídos ­ 412 com FA paroxística e 181 com FA persistente. Durante o seguimento médio de 24±6 meses, 76,4% não apresentaram recidiva após ablação. Individualmente, os biomarcadores demonstraram um valor preditivo baixo ou nulo para recorrência. No entanto, TSH >1,8 µUI/mL [HR=1,82 (IC95%, 1,89-2,80), p=0,006] foi um preditor independente de recorrência. Avaliando-se a combinação de TSH, FT4 e BNP, a adição de cada valor "anormal" foi associada a uma menor sobrevida livre de recorrência (87,1% se nenhum vs. 83,5% se um vs. 75,1% se dois vs. 43,3% se três biomarcadores, p<0,001). Doentes com três biomarcadores "anormais" apresentaram três vezes maior probabilidade de recorrência de FA, comparativamente aos que não apresentaram nenhum biomarcador "anormal" (HR=2,88 [IC95%, 1,39-5,17], p=0,003). CONCLUSÕES: Quando combinados, valores anormais de TSH, FT4 e BNP podem ser uma ferramenta útil para prever a recorrência de FA pós ablação guiada pelo AI.


Atrial Fibrillation , Biomarkers , Catheter Ablation , Recurrence , Thyrotropin , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/blood , Biomarkers/blood , Male , Female , Prospective Studies , Middle Aged , Catheter Ablation/methods , Aged , Thyrotropin/blood , Natriuretic Peptide, Brain/blood , Predictive Value of Tests , C-Reactive Protein/analysis , Treatment Outcome , Thyroxine/blood , Risk Factors , Troponin I/blood
3.
BMJ Open ; 14(5): e079881, 2024 May 09.
Article En | MEDLINE | ID: mdl-38724059

OBJECTIVES: Pulsed field ablation (PFA) is a promising new ablation modality for the treatment of atrial fibrillation (AF) that has recently become available in the UK National Health Service (NHS). We provide the first known economic evaluation of the technology. METHODS: A cost-comparison model was developed to compare the expected 12-month costs of treating AF using the pentaspline PFA catheter compared with cryoablation for a single hypothetical patient. Model parameters were based on a recent cost-effectiveness analysis by the National Institute for Health and Care Excellence where possible or published literature otherwise. Deterministic sensitivity, scenario and threshold analyses were conducted. RESULTS: Costs for a single patient treated with PFA were -3% (-£343) less over 12 months than those who received treatment with cryoablation. PFA was associated with 16% higher catheter costs but repeat ablation costs were over 50% less, driven by a reduction in repeat ablations required. Costs of managing complications were -£211 less in total for PFA compared with cryoablation. CONCLUSIONS: Routine adoption of PFA with the pentaspline PFA catheter looks to be as affordable for the NHS as current treatment alternative cryoablation.


Atrial Fibrillation , Catheter Ablation , Cost-Benefit Analysis , Cryosurgery , State Medicine , Atrial Fibrillation/surgery , Atrial Fibrillation/economics , Atrial Fibrillation/therapy , Humans , Cryosurgery/economics , Cryosurgery/methods , United Kingdom , Catheter Ablation/economics , Catheter Ablation/methods , State Medicine/economics
4.
Zhonghua Gan Zang Bing Za Zhi ; 32(4): 332-339, 2024 Apr 20.
Article Zh | MEDLINE | ID: mdl-38733188

Objective: To evaluate the long-term efficacy of percutaneous microwave ablation (MWA) therapy for hepatocellular carcinoma. Methods: 2054 cases with Barcelona Clinic Liver Cancer (BCLC) stage 0~B at the Fifth Medical Center of the Chinese People's Liberation Army General Hospital from January 2006 to September 2020 were retrospectively collected. All patients were followed up for at least 2 years. The primary endpoint of overall survival and secondary endpoints (tumor-related survival, disease-free survival, and postoperative complications) of patients treated with ultrasound-guided percutaneous MWA were analyzed. Kaplan-Meier method was used for stratified survival rate analysis. Fine-and-Gray competing risk model was used to analyze overall survival. Results: A total of 5 503 HCC nodules [mean tumor diameter (2.6±1.6) cm] underwent 3 908 MWAs between January 2006 and September 2020, with a median follow-up time of 45.6 (24.0 -79.2) months.The technical effectiveness rate of 5 375 tumor nodules was 97.5%. The overall survival rates at 5, 10, and 15-years were 61.6%, 38.8%, and 27.0%, respectively. The tumor-specific survival rates were 67.1%, 47.2%, and 37.7%, respectively. The free tumor survival rates were 25.8%, 15.7%, and 9.9%, respectively. The incidence rate of severe complications was 2.8% (108/3 908). Further analysis showed that the technical effectiveness and survival rate over the passing three time periods from January 2006-2010, 2011-2015, and 2016-September 2020 were significantly increased, with P < 0.001, especially for liver cancer 3.1~5.0 cm (P < 0.001). Conclusion: Microwave ablation therapy is a safe and effective method for BCLC stage 0-B, with significantly enhanced technical efficacy and survival rate over time.


Carcinoma, Hepatocellular , Liver Neoplasms , Microwaves , Humans , Liver Neoplasms/surgery , Liver Neoplasms/therapy , Carcinoma, Hepatocellular/therapy , Carcinoma, Hepatocellular/surgery , Microwaves/therapeutic use , Retrospective Studies , Survival Rate , Treatment Outcome , Disease-Free Survival , Catheter Ablation/methods , Female , Postoperative Complications/epidemiology , Male , Middle Aged
5.
BMC Cardiovasc Disord ; 24(1): 246, 2024 May 10.
Article En | MEDLINE | ID: mdl-38730404

BACKGROUND: Clinical outcomes after catheter ablation (CA) or pacemaker (PM) implantation for the tachycardia-bradycardia syndrome (TBS) has not been evaluated adequately. We tried to compare the efficacy and safety outcomes of CA and PM implantation as an initial treatment option for TBS in paroxysmal atrial fibrillation (AF) patients. METHODS: Sixty-eight patients with paroxysmal AF and TBS (mean 63.7 years, 63.2% male) were randomized, and received CA (n = 35) or PM (n = 33) as initial treatments. The primary outcomes were unexpected emergency room visits or hospitalizations attributed to cardiovascular causes. RESULTS: In the intention-to-treatment analysis, the rates of primary outcomes were not significantly different between the two groups at the 2-year follow-up (19.8% vs. 25.9%; hazard ratio (HR) 0.73, 95% confidence interval (CI) 0.25-2.20, P = 0.584), irrespective of whether the results were adjusted for age (HR 1.12, 95% CI 0.34-3.64, P = 0.852). The 2-year rate of recurrent AF was significantly lower in the CA group compared to the PM group (33.9% vs. 56.8%, P = 0.038). Four patients (11.4%) in the CA group finally received PMs after CA owing to recurrent syncope episodes. The rate of major or minor procedure related complications was not significantly different between the two groups. CONCLUSION: CA had a similar efficacy and safety profile with that of PM and a higher sinus rhythm maintenance rate. CA could be considered as a preferable initial treatment option over PM implantation in patients with paroxysmal AF and TBS. TRIAL REGISTRATION: KCT0000155.


Atrial Fibrillation , Bradycardia , Cardiac Pacing, Artificial , Catheter Ablation , Heart Rate , Pacemaker, Artificial , Recurrence , Humans , Male , Female , Middle Aged , Catheter Ablation/adverse effects , Prospective Studies , Treatment Outcome , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Atrial Fibrillation/therapy , Atrial Fibrillation/surgery , Bradycardia/diagnosis , Bradycardia/therapy , Bradycardia/physiopathology , Cardiac Pacing, Artificial/adverse effects , Time Factors , Risk Factors , Syndrome , Tachycardia/physiopathology , Tachycardia/diagnosis , Tachycardia/therapy , Tachycardia/surgery
6.
Int J Mol Sci ; 25(9)2024 Apr 25.
Article En | MEDLINE | ID: mdl-38731908

In atrial fibrillation (AF), multifactorial pathologic atrial alterations are manifested by structural and electrophysiological changes known as atrial remodeling. AF frequently develops in the context of underlying cardiac abnormalities. A critical mechanistic role played by atrial stretch is played by abnormal substrates in a number of conditions that predispose to AF, including obesity, heart failure, hypertension, and sleep apnea. The significant role of overweight and obesity in the development of AF is known; however, the differential effect of overweight, obesity, cardiovascular comorbidities, lifestyle, and other modifiable risk factors on the occurrence and recurrence of AF remains to be determined. Reverse remodeling of the atrial substrate and subsequent reduction in the AF burden by conversion into a typical sinus rhythm has been associated with weight loss through lifestyle changes or surgery. This makes it an essential pillar in the management of AF in obese patients. According to recently published research, microRNAs (miRs) may function as post-transcriptional regulators of genes involved in atrial remodeling, potentially contributing to the pathophysiology of AF. The focus of this review is on their modulation by both weight loss and catheter ablation interventions to counteract atrial remodeling in AF. Our analysis outlines the experimental and clinical evidence supporting the synergistic effects of weight loss and catheter ablation (CA) in reversing atrial electrical and structural remodeling in AF onset and in recurrent post-ablation AF by attenuating pro-thrombotic, pro-inflammatory, pro-fibrotic, arrhythmogenic, and male-sex-associated hypertrophic remodeling pathways. Furthermore, we discuss the promising role of miRs with prognostic potential as predictive biomarkers in guiding approaches to AF recurrence prevention.


Atrial Fibrillation , Biomarkers , Catheter Ablation , MicroRNAs , Weight Loss , Atrial Fibrillation/metabolism , Atrial Fibrillation/genetics , Atrial Fibrillation/etiology , Humans , MicroRNAs/genetics , MicroRNAs/metabolism , Catheter Ablation/methods , Recurrence , Atrial Remodeling , Animals , Obesity/metabolism , Obesity/complications
7.
Med Sci Monit ; 30: e943526, 2024 May 12.
Article En | MEDLINE | ID: mdl-38734884

BACKGROUND A significant number of atrial fibrillation (AF) recurrences occur after initial ablation, often due to pulmonary vein reconnections or triggers from non-pulmonary veins. MATERIAL AND METHODS Patients with paroxysmal AF who underwent radiofrequency catheter ablation for the first time were enrolled. Base on propensity score matching (1: 1 matching), 118 patients were selected for an optimized workflow for the radiofrequency catheter ablation of paroxysmal AF (OWCA) group and a conventional group. Comparative analysis of the acute and 12-month clinical outcomes was conducted. Moreover, an artificial intelligence analytics platform was used to evaluate the quality of pulmonary vein isolation (PVI) circles. RESULTS PVI was successfully achieved in all patients. Incidence of first-pass isolation of bilateral PVI circles was higher (P=0.009) and acute pulmonary vein reconnections was lower (P=0.027) in the OWCA group than conventional group. The OWCA group displayed a significant reduction in the number of fractured points (P<0.001), stacked points (P=0.003), and a greater proportion of cases in which the radiofrequency index achieved the target value (P=0.003). Additionally, the contact force consistently met the force over time criteria (P<0.001) for bilateral PVI circles in the OWCA group, accompanied by a shorter operation time (P=0.017). During the 12-month follow-up period, the OWCA group exhibited a higher atrial arrhythmia-free survival rate following the initial ablation procedure than did the conventional group. CONCLUSIONS The optimized workflow for radiofrequency catheter ablation of paroxysmal AF could play a crucial role in creating higher quality PVI circles. This improvement is reflected in a significantly elevated 12-month atrial arrhythmia-free survival rate.


Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Workflow , Humans , Atrial Fibrillation/surgery , Catheter Ablation/methods , Female , Male , Middle Aged , Treatment Outcome , Pulmonary Veins/surgery , Aged , Propensity Score , Recurrence
9.
Rev Assoc Med Bras (1992) ; 70(4): e2023D704, 2024.
Article En | MEDLINE | ID: mdl-38747880

The Guidelines Project, which is an initiative of the Brazilian Medical Association, aims to combine information from the medical field to standardize how to conduct and assist in the reasoning and decision-making of doctors. The information provided by this project must be critically evaluated by the physician responsible for the conduct that will be adopted, depending on the conditions and the clinical condition of each patient.


Hypertension , Kidney , Humans , Hypertension/surgery , Kidney/innervation , Treatment Outcome , Sympathectomy/methods , Catheter Ablation/methods
11.
Europace ; 26(5)2024 May 02.
Article En | MEDLINE | ID: mdl-38693772

AIMS: Arrhythmia-induced cardiomyopathy (AiCM) represents a subtype of acute heart failure (HF) in the context of sustained arrhythmia. Clear definitions and management recommendations for AiCM are lacking. The European Heart Rhythm Association Scientific Initiatives Committee (EHRA SIC) conducted a survey to explore the current definitions and management of patients with AiCM among European and non-European electrophysiologists. METHODS AND RESULTS: A 25-item online questionnaire was developed and distributed among EP specialists on the EHRA SIC website and on social media between 4 September and 5 October 2023. Of the 206 respondents, 16% were female and 61% were between 30 and 49 years old. Most of the respondents were EP specialists (81%) working at university hospitals (47%). While most participants (67%) agreed that AiCM should be defined as a left ventricular ejection fraction (LVEF) impairment after new onset of an arrhythmia, only 35% identified a specific LVEF drop to diagnose AiCM with a wide range of values (5-20% LVEF drop). Most respondents considered all available therapies: catheter ablation (93%), electrical cardioversion (83%), antiarrhythmic drugs (76%), and adjuvant HF treatment (76%). A total of 83% of respondents indicated that adjuvant HF treatment should be started at first HF diagnosis prior to antiarrhythmic treatment, and 84% agreed it should be stopped within six months after LVEF normalization. Responses for the optimal time point for the first LVEF reassessment during follow-up varied markedly (1 day-6 months after antiarrhythmic treatment). CONCLUSION: This EHRA Survey reveals varying practices regarding AiCM among physicians, highlighting a lack of consensus and heterogenous care of these patients.


Arrhythmias, Cardiac , Cardiomyopathies , Humans , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/physiopathology , Female , Male , Cardiomyopathies/therapy , Cardiomyopathies/diagnosis , Cardiomyopathies/physiopathology , Middle Aged , Adult , Europe , Surveys and Questionnaires , Stroke Volume , Health Care Surveys , Anti-Arrhythmia Agents/therapeutic use , Practice Patterns, Physicians'/statistics & numerical data , Ventricular Function, Left , Catheter Ablation , Cardiologists
12.
Europace ; 26(5)2024 May 02.
Article En | MEDLINE | ID: mdl-38696675

AIMS: Contact force (CF)-sensing radiofrequency (RF) catheters with an ablation index have shown reproducible outcomes for the treatment of atrial fibrillation (AF) in large multicentre studies. A dual-energy (DE) focal CF catheter to deliver RF and unipolar/biphasic pulsed field ablation (PFA), integrated with a three-dimensional (3D) mapping system, can provide operators with additional flexibility. The SmartfIRE study assessed the safety and efficacy of this novel technology for the treatment of drug-refractory, symptomatic paroxysmal AF. Results at 3 months post-ablation are presented here. METHODS AND RESULTS: Pulmonary vein isolation (PVI) was performed using a DE focal, irrigated CF-sensing catheter with the recommendation of PFA at posterior/inferior and RF ablation at the anterior/ridge/carina segments. Irrespective of energy, a tag size of 3 mm; an inter-tag distance ≤6 mm; a target index of 550 for anterior, roof, ridge, and carina; and a target index of 400 for posterior and inferior were recommended. Cavotricuspid isthmus ablation was permitted in patients with documented typical atrial flutter. The primary effectiveness endpoint was acute procedural success. The primary safety endpoint was the rate of primary adverse events (PAEs) within 7 days of the procedure. A prespecified patient subset underwent oesophageal endoscopy (EE; 72 h post-procedure), neurological assessment (NA; pre-procedure and discharge), and cardiac computed tomography (CT)/magnetic resonance angiogram (MRA) imaging (pre-procedure and 3 months post-procedure) for additional safety evaluation, and a mandatory remapping procedure (Day 75 ± 15) for PVI durability assessment. Of 149 patients enrolled between February and June 2023, 140 had the study catheter inserted (safety analysis set) and 137 had ablation energy delivered (per-protocol analysis set). The median (Q1/Q3) total procedure and fluoroscopy times were 108.0 (91.0/126.0) and 4.2 (2.3/7.7) min (n = 137). The acute procedural success rate was 100%. First-pass isolation was achieved in 89.1% of patients and 96.8% of veins. Cavotricuspid isthmus ablations were successfully performed in 12 patients [pulsed field (PF) only: 6, RF only: 5, and RF/PF: 1]. The PAE rate was 4.4% [6/137 patients; 2 pulmonary vein (PV) stenoses, 2 cardiac tamponades/perforations, 1 stroke, and 1 pericarditis]. No coronary artery spasm was reported. No oesophageal lesion was seen in the EE subset (0/31, 0%). In the NA subset (n = 30), microemboli lesions were identified in 2 patients (2/30, 6.7%), both of which were resolved at follow-up; only 1 was symptomatic (silent cerebral lesion, 3.3%). In the CT/MRA subset (n = 30), severe PV narrowing (of >70%) was detected in 2 patients (2/30, 6.7%; vein level 2/128, 1.6%), of whom 1 underwent dilatation and stenting and 1 was asymptomatic; both were associated with high index values and a small inter-tag distance. In the PV durability subset (n = 30), 100/115 treated PVs (87%) were durably isolated and 18/30 patients (60.0%) had all PVs durably isolated. CONCLUSION: A DE focal CF catheter with 3D mapping integration showed a 100% acute success rate with an acceptable safety profile in the treatment of paroxysmal AF. Prespecified 3-month remapping showed notable PVI durability. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT05752487.


Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Pulmonary Veins/surgery , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Male , Female , Catheter Ablation/methods , Catheter Ablation/instrumentation , Middle Aged , Treatment Outcome , Aged , Imaging, Three-Dimensional , Cardiac Catheters , Time Factors , Equipment Design , Prospective Studies , Recurrence
13.
Clin Interv Aging ; 19: 715-725, 2024.
Article En | MEDLINE | ID: mdl-38716143

Objective: Atrial fibrillation (AF) is a common arrhythmia. This study explored serum miR-29b-3p expression in AF patients and its value in predicting AF recurrence after radiofrequency catheter ablation (RFCA). Methods: Totally 100 AF patients who underwent RFCA were enrolled, with 100 individuals without AF as controls. Serum miR-29b-3p expression in participants was determined using RT-qPCR. The correlation between miR-29b-3p and atrial fibrosis markers (FGF-21/FGF-23) was assessed by Pearson analysis. The diagnostic efficacy of serum miR-29b-3p and FGF-21/FGF-23 in predicting AF recurrence after RFCA was analyzed by the receiver operating characteristic (ROC) curves. The Kaplan-Meier method was adopted to evaluate the effect of miR-29b-3p expression on the incidence of AF recurrence after RFCA. The independent risk factors for AF recurrence after RFCA were analyzed by logistic regression analysis. Results: Serum miR-29b-3p was poorly expressed in AF patients. After RFCA, AF patients showed elevated serum miR-29b-3p expression. Serum miR-29b-3p expression in AF patients negatively correlated with serum FGF-21 and FGF-23 concentrations. The cut-off values of serum miR-29b-3p, FGF-21, and FGF-23 in identifying AF recurrence were 0.860 (sensitivity: 100.00%, specificity: 39.71%), 222.2 pg/mL (sensitivity: 96.88%, specificity: 32.35%) and 216.3 ng/mL (sensitivity: 53.13%, specificity: 70.59%), respectively. Patients with low miR-29b-3p expression had a significantly higher incidence of AF recurrence than patients with high miR-29b-3p expression. Serum miR-29b-3p expression was one of the independent risk factors for AF recurrence after RFCA. Conclusion: Low miR-29b-3p expression in AF patients has certain predictive values and is one of the independent risk factors for AF recurrence after RFCA.


Atrial Fibrillation , Catheter Ablation , MicroRNAs , Recurrence , Humans , Atrial Fibrillation/blood , Male , Female , MicroRNAs/blood , Middle Aged , Fibroblast Growth Factor-23 , Aged , Risk Factors , ROC Curve , Predictive Value of Tests , Biomarkers/blood , Fibroblast Growth Factors/blood
14.
Radiol Technol ; 95(5): 321-326, 2024 May.
Article En | MEDLINE | ID: mdl-38719553

BACKGROUND: This case details a 44-year-old man with end-stage ischemic cardiomyopathy with refractory ventricular tachycardia (VT). The patient has a single-chamber implantable cardioverter-defibrillator, has had 2 VT ablations, and uses medication to manage his VT. Despite these interventions, he continued to have episodes of VT. The patient underwent stereotactic body radiation therapy (SBRT) to help reduce the burden of his VT. The patient received a dose of 25 Gy to his right inferior lateral region of the heart and a dose of 15 Gy to the inferior portion of the heart closer to the stomach. The patient followed up 1 month later and reported that his energy levels improved and that no arrhythmias had occurred since his SBRT treatment. DISCUSSION: The options for treating end-stage VT are limited. However, a treatment option using SBRT has been introduced to reduce the VT burden in patients. Cardiac SBRT is a noninvasive outpatient procedure that, while still awaiting U.S. Food and Drug Administration approval, reduces arrhythmia episodes and offers favorable short-term benefits for patients who have not responded to traditional treatment modalities. CONCLUSION: Cardiac SBRT is a novel treatment for VT in patients where standard treatments have failed. This case study demonstrates that SBRT effectively reduced arrhythmias in a patient with VT. The long-term clinical outcomes are not known, but the opportunity SBRT offers for treatment-refractory patients is favorable and should be considered.


Radiosurgery , Tachycardia, Ventricular , Humans , Male , Tachycardia, Ventricular/surgery , Adult , Radiosurgery/methods , Defibrillators, Implantable , Catheter Ablation/methods
15.
Kyobu Geka ; 77(5): 369-372, 2024 May.
Article Ja | MEDLINE | ID: mdl-38720607

An 81-year-old man underwent total arch replacement for thoracic aortic aneurysm 8 years ago and catheter ablation for paroxysmal atrial fibrillation 1 year ago. Transthoracic echocardiography revealed a mass in the right atrium, and the patient was admitted for close examination and treatment. Transesophageal echocardiography revealed a 23×17 mm large well-defined mass above the cavotricuspid isthmus. Two venous drainage cannulas were inserted directly to the superior vena cava and to the inferior vena cava via the right femoral vein, in order to avoid the direct contact with the right atrium prior to institution of cardiopulmonary bypass. The right atrial tumor was found attached to the cavotricuspid isthmus, and was resected together with the right atrial wall. Pathological examination showed myxomatous tissue. Postoperative course was uneventful. He was discharged 23 days after the operation.


Catheter Ablation , Heart Atria , Heart Neoplasms , Myxoma , Humans , Myxoma/surgery , Myxoma/diagnostic imaging , Male , Aged, 80 and over , Heart Neoplasms/surgery , Heart Neoplasms/diagnostic imaging , Heart Atria/surgery
17.
J Vis Exp ; (206)2024 Apr 19.
Article En | MEDLINE | ID: mdl-38709062

Radiofrequency (RF) ablation to perform pulmonary vein isolation (PVI) for the treatment of atrial fibrillation involves some risk to collateral structures, including the esophagus. Proactive esophageal cooling using a dedicated device has been granted marketing authorization by the Food and Drug Administration (FDA) to reduce the risk of ablation-related esophageal injury due to RF cardiac ablation procedures, and more recent data also suggest that esophageal cooling may contribute to improved long-term efficacy of treatment. A mechanistic underpinning explaining these findings exists through the quantification of lesion placement contiguity defined as the Continuity Index (CI). Kautzner et al. quantified the CI by the order of lesion placement, such that whenever a lesion is placed non-adjacent to the prior lesion, the CI is incremented by the number of segments the catheter tip has moved over. To facilitate real-time calculation of the CI and encourage further adoption of this instrument, we propose a modification in which the placement of non-adjacent lesions increments the CI by only one unit, avoiding the need to count potentially nebulous markers of atrial segmentation. The objective of this protocol is to describe the methods of calculating the CI both prospectively during real-time PVI cases and retrospectively using recorded case data. A comparison of the results obtained between cases that utilized proactive esophageal cooling and cases that used luminal esophageal temperature (LET) monitoring is then provided.


Atrial Fibrillation , Catheter Ablation , Esophagus , Atrial Fibrillation/surgery , Esophagus/surgery , Humans , Catheter Ablation/methods , Catheter Ablation/instrumentation , Pulmonary Veins/surgery
18.
19.
Clin Imaging ; 110: 110170, 2024 Jun.
Article En | MEDLINE | ID: mdl-38696998

INTRODUCTION: In patients with atrial fibrillation (AF), up to one third have recurrence after a first catheter ablation (CA). Epicardial adipose tissue (EAT) has been considered to be closely related to AF, with a potential role in its recurrence. We aimed to evaluate the association between the volume of EAT measured by cardiac computed tomography (CT) and AF recurrence after CA. METHODS: Consecutive AF patients underwent a standardized cardiac CT protocol for quantification of EAT, thoracic adipose volume (TAV) and left atrium (LA) volume before CA. An appropriate cut-off of EAT was determined and risk recurrence was estimated. RESULTS: 305 patients (63.6 % male, mean age 57.5 years, 28.2 % persistent AF) were followed for 24 months; 23 % had AF recurrence at 2-year mark, which was associated with higher EAT (p = 0.037) and LAV (p < 0.001). Persistent AF was associated with higher EAT volumes (p = 0.010), TAV (p = 0.003) and LA volumes (p < 0.001). EAT was predictive of AF recurrence (p = 0.044). After determining a cut-off of 92 cm3, survival analysis revealed that EAT volumes > 92 cm3 showed higher recurrence rates at earlier time points after the index ablation procedure (p = 0.006), with a HR of 1.95 (p = 0.008) of AF recurrence at 2-year. After multivariate adjustment, EAT > 92 cm3 remained predictive of AF recurrence (p = 0.028). CONCLUSION: The volume of EAT measured by cardiac CT can predict recurrence of AF after ablation, with a volume above 92 cm3 yielding almost twice the risk of arrhythmia recurrence in the first two years following CA. Higher EAT and TAV are also associated with persistent AF.


Adipose Tissue , Atrial Fibrillation , Catheter Ablation , Pericardium , Recurrence , Tomography, X-Ray Computed , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/diagnostic imaging , Male , Female , Adipose Tissue/diagnostic imaging , Middle Aged , Catheter Ablation/methods , Pericardium/diagnostic imaging , Pericardium/pathology , Tomography, X-Ray Computed/methods , Predictive Value of Tests , Aged , Treatment Outcome , Epicardial Adipose Tissue
20.
Europace ; 26(5)2024 May 02.
Article En | MEDLINE | ID: mdl-38647070

AIMS: Simplified ablation technologies for pulmonary vein isolation (PVI) are increasingly performed worldwide. One of the most common complications following PVI are vascular access-related complications. Lately, venous closure systems (VCSs) were introduced into clinical practice, aiming to reduce the time of bed rest, to increase the patients' comfort, and to reduce vascular access-related complications. The aim of the present study is to compare the safety and efficacy of using a VCS to achieve haemostasis following single-shot PVI to the actual standard of care [figure-of-eight suture and manual compression (MC)]. METHODS AND RESULTS: This is a prospective, multicentre, randomized, controlled, open-label trial performed at three German centres. Patients were randomized 1:1 to undergo haemostasis either by means of VCS (VCS group) or of a figure-of-eight suture and MC (F8 group). The primary efficacy endpoint was the time to ambulation, while the primary safety endpoint was the incidence of major periprocedural adverse events until hospital discharge. A total of 125 patients were randomized. The baseline characteristics were similar between the groups. The VCS group showed a shorter time to ambulation [109.0 (82.0, 160.0) vs. 269.0 (243.8, 340.5) min; P < 0.001], shorter time to haemostasis [1 (1, 2) vs. 5 (2, 10) min; P < 0.001], and shorter time to discharge eligibility [270 (270, 270) vs. 340 (300, 458) min; P < 0.001]. No major vascular access-related complication was reported in either group. A trend towards a lower incidence of minor vascular access-related complications on the day of procedure was observed in the VCS group [7 (11.1%) vs. 15 (24.2%); P = 0.063] as compared to the control group. CONCLUSION: Following AF ablation, the use of a VCS results in a significantly shorter time to ambulation, time to haemostasis, and time to discharge eligibility. No major vascular access-related complications were identified. The use of MC and a figure-of-eight suture showed a trend towards a higher incidence of minor vascular access-related complications.


Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Suture Techniques , Humans , Atrial Fibrillation/surgery , Female , Male , Middle Aged , Catheter Ablation/adverse effects , Catheter Ablation/methods , Prospective Studies , Pulmonary Veins/surgery , Suture Techniques/adverse effects , Aged , Treatment Outcome , Germany , Time Factors , Vascular Closure Devices , Early Ambulation , Hemostatic Techniques/instrumentation
...